SA-8850S
The Arena SA-8850S features an AMCC PPC440SP CPU, dual U320 SCSI channels, twenty four SATA-II drive bays, and fully modularized componentsand hot swappable power supplies and fans to reduce the amount of operating downtime for maintenance. The system supports RAID 6 to further increase data integrity and reliability.

Overview

Ideal Applications

- Enterprise Storage
- Disk to Disk Backup
- Performance Driven HD
- Video Streaming Applications
- Security and Surveillance
- Regulation Compliance Storage
- Disaster Recovery Storage
- Audio and Video Editing
- VOD on Education or Entertainment
- Fixed Content Archiving

Specification

Hardware
Controller Single
Controller CPU AMCC PPC440SP CPU
Cache Memory 1024 - 4096 MB DDR II
Battery Backup Optional
Host Interface U320 SCSI
Host Channels No. 2
Disk Interface SATA II (3Gb/s)
Number of Disk Channels 24
Hot Swap Disk Tray 3.5" hot-swappable tray
Data Transfer Rate Up to 320MBps per port
External Connector Type VHDCI
Hot Swap Fan 4 x Turbo Fan
Hot Swap Power supplies 350 W, Redundant 2+1
AC Input Voltage 100 to 240V (+/- 10%), 47 to 63 Hz
Online Expansion Yes
Raid Function
RAID Levels JBOD, 0, 1, 3, 5, 6, 10, 30, 50, 60, NRAID
RAID Features - Global and local hotspare
- Multiple Host ID
- Background Initialization
Advanced Data Reliability Assurance SMARTCor. Function (DST, DS, DC)
RAID Management
Front Panel LCD and Buttons Easy access for configuration and status report
Management AP PathGuard, RAIDGuard Central, Windows MPIO, Windows VDS 1.1
RS-232 Terminal User Friendly interface for configuration and status report
Event Notification Built-in buzzer, e-mail, and SNMP
Web browser GUI Embedded GUI management interface
Environment
Humidity 20% to 80% non-condensing
Operating Temp 5 °C to 40 °C (41 °F~104 °F)
Non-Operating Temp -25 °C to 60 °C (-13 °F~104 °F)
Safety Regulatory UL, CUL, CB
EMC Standard FCC, CE, C-Tick, BSMI
Dimension & Weight
Physical Dimensions 485(W) x 565(D) x 176(H) mm
Physical Weight 34 Kgs (without drives)
Packed Dimensions 635(W) x 805(D) x 565(H) mm
Packed Weight 43 Kgs (without drives)
*1. Support SATA drive requires AA-MUX tray board.
*2. Specifications and product offerings may vary without notice.
*3. Various trademarks belong to their respective owners.

Key Features

Innovative New Array Stucture

The system features a new innovate array structure that hierarchically organizes storage objects. With this structure, physical drives are combined into Disk Groups (DG). Disk Groups are subdivided into Logical Disks (LD) where arrays are created. Lastly, Logical Disk can be combined or stripped together to form Volumes. Either volumes or LD can be pointed to a LUN which are then presented to the host computer.
Online Expansion and Defragmentation of Disks Groups

New physical disks can be added by expansion of a Disk Group (DG) while the unit remains online. During the process of expanding Disk Groups, defragmentation can be selected to move unused capacity to the ending LBA of a Disk Group. Defragmentation can also be selected at anytime there is unused storage space residing between Logical Disks.
Online Expansion and Shrinking of Logical Disks

Logical Disk (LD) Online Expansion can increase the capacity of an online LUN, instead of having to create a separate partition for unused capacity or capacity gained from Disk Group Expansion; now your storage can dynamically grow as your demands grow. In the event of overestimating requirements for Logical Disk capacity, shrinking can be used reduce the allocated storage of a Logical Disk.
Array Recovery Ulitity

The system now provides an Array Recovery Utility (ARU) that can aid a user in the event of multiple drive failures corrupting the RAID array of a Logical Disk and/or volumes. The ARU enables users to recover lost disk members of a Disk Group, and will automatically recover Logical Disks and Volumes.
Global or local spare disks

With the new storage structure, local and global spares can be configured. Local spares will belong to specific Disk Groups and will only replace faulty drives in a specific Disk Group. Meanwhile, Global Spares will replace faulty disk in any available Disk Group.
Dual Flash Rom/strong>

Dual Flash ROM per controller gives higher RAID system availability and reliability during firmware upgrading or in the event of a single ROM failure.
Web-based GUI

A simplified feature of Disk Scrubbing (DS), Regenerate Parity will regenerate the parity of a Logical Disk(s) in a Disk Group without a parity check.
Raid 6

RAID 6 improves over the industry standard RAID 5 by adding another parity disk which gives greater reliability and data protection.
Disks Self-Test

Before the release of this function, users of RAID systems were forced to test suspected bad hard drives in a host computer individually using a drive manufacturer’s utility. This function tests the health of hard drives with them installed in the RAID unit. DST performs write tests, servo analysis, and read scan tests; the test results are then displayed on the LCD and hyper terminal output. This can aid the user in deciding whether or not to replace a suspected failing hard drive. We highly recommend running this test before initializing a RAID set to ensure a healthy RAID solution.
Disks scrubbing

With today’s RAID subsystems being capable of storing multiple terabytes, it is becoming increasingly difficult to manage and maintain that large amount of data. To aid a user in maintaining their data’s health, Arena-MaxTronic has released their newest firmware function Disk Scrubbing. The data and/or parity stored on hard drives can sometimes become corrupted; this data can also reside in areas that are not accessed for long periods of time. DS will use idle time to test the disks, and if a sector is found to be corrupted, the data will be regenerated from other RAID member disks and will be written to an uncorrupted sector. The purpose of DS is to prevent the possibility of having multiple corrupted sectors in a single stripe, which is one of the main causes of data loss.
Disks Clone

Hard drives are the most likely component to fail in a RAID array, and almost impossible to predict when the failure will occur. When a failure does occur the RAID unit will have to regenerate data from the non-failed hard drives to rebuild a new drive, and the RAID array will be in degraded mode. Having a unit in degraded mode is a very cautious time because if a second hard drive was to fail the RAID is destroyed and data is lost. This is where Disk Cloning can aide a user. With the help of the hard drives built in S.M.A.R.T. function, DC can determine when to begin cloning a bad drive to a hot spare. Upon completion of cloning, the new cloned disk can take the position of the failing disk or can stand-by until the original disk fails, then take the failed disks position. Disk cloning is to prevent a rebuild from ever occurring and having the unit in degraded mode.
Support greater than 2TB Lun

Two firmware options are available to surpass the 2 terabyte limitation; 16byte CDB and variable sector size. With either of these functions enabled, users are able to create slices and map LUNs greater than 2TB to their respective host channels. See support documentation for compatibility or contact technical support for more information.
Background Initialization

Initialization occurs during creation of a RAID array by zeroing out / formatting drives. By default the initialization process occurs with the unit offline, and inaccessible. With background initialization, the RAID array can be accessed during the initialization process so that the unit can be setup without having to wait several hours to complete initialization.
BBM

An optional BBM can be included in the RAID system to ensure data integrity in the event of a power outage. The BBM, or battery backup module, will provide power to the on-board cache of the RAID controller in the event of a power outage. This will allow any data that is still stored on the cache to be saved until power is restored. Once power is restored, the RAID controller will flush the cache to drives.

Downloads

User Manual: Hardware
SA-8850S Datasheet

GUI Preview

Spare Parts

Photo Part No. Part Name Qty
49-08850-5000-001 Controller Module, for SA-8850S 1 piece
46-81000-5000-102 Controller Board, for SA-8850S 1 piece
46-92100-5010-100 Back Plane, for 4U 24bays 1 piece
46-08990-5000-120 LCD Button Board 1 piece
51-30000-5004 Power Supply, 350W 1 piece
46-92100-5060-010 I/O Board 1 piece
42-01620-5013 HDD Tray 1 piece
49-00001-5900-001 Fan Set, for 4U Series 1 piece
51-60000-5001 Rail 1 piece
42-00000-5010 Extender 1 piece
42-36000-5004 Key, 2 pcs 1 pack
43-00003-5080 Power Cable-US, L=180cm 1 piece
43-00003-5090 Power Cable-EU, L=180cm 1 piece
43-00003-5100 Power Cable-AUS, L=180cm 1 piece
43-00003-5110 Power Cable-PSE, L=180cm 1 piece
43-00003-5120 Power Cable-UK, L=180cm 1 piece
43-00009-5080 RS232 Cable, L=180cm 1 piece
43-00320-5010 SCSI Cable, HPD-VHDCI (plastic), L=100cm 1 piece
43-00320-5020 SCSI Cable, VHDCI-VHDCI (plastic), L=100cm 1 piece
43-00001-5002 SCSI Cable, HPD-VHDCI, L=100cm 1 piece
43-00001-5003 SCSI Cable, VHDCI-VHDCI, L=100cm 1 piece
51-50000-5003 Terminator, LVD/SE VHDCI 1 piece
42-24632-5001 Screw #6/325mm, 30pcs 1 piece
42-24545-5001 Screw #M5, 2pcs 1 pack
42-24645-5001 Screw #M6, 2pcs 1 pack
42-24045-5001 Screw, #10/32, 2pcs 1 pack
49-00003-5011-001 BBM 1 piece