go to homepage
SS-4501E
The Redundant RAID system setup an important milestone for MaxTronic entering into the Critical high-end enterprise demands. With active-active redundant controller architecture for full failover, the latest 4Gb FC-SAS host interface with advanced high performance CPU supports higher data operation rate. Powerful hardware engine, high scalable expansion options and user-friendly management interface make it the best choice for fault tolerance, high performance solutions.

Photo

Idea Application

- Enterprise Storage
- Disk to Disk Backup
- Performance Driven HD
- Video Streaming Applications
- Security and Surveillance
- Regulation Compliance Storage
- Disaster Recovery Storage
- Audio and Video Editing
- VOD on Education or Entertainment
- Fixed Content Archiving

Specification

<
Hardware
Controller Single
Controller CPU AMCC PPC440SP
Cache Memory 2048 - 4096 MB DDR II
Battery Backup Module Optional
Host Interface 4Gb Fibre Channel (SFP*)
Host Channels No. 2
Disk Interface SATA II (3Gbps)
Number of Disk Channels 16
Hot Swap Disk Tray 3.5" hot-swappable tray
Data Transfer Rate up to 400 Mbps
External Connector Type SFP
Hot Swap Fant 2 x Turbo Fan
Hot Swap Power suppliesg 460W x 2 Redundant
AC Input Voltage 100 to 240V (+/- 10%), 47 to 63 Hz
RAID Functions
RAID Levels JBOD, 0, 1, 3, 5, 6, 10, 30, 50, 60, NRAID
RAID Features Global and local hotspare, and Background Initialization
Advanced Data Reliability Assurance SMARTCor. Functions (DST, DS, DC)
Front Panel LCD and Buttons Easy access for configuration and status report
RS-232 Terminal User friendly interface for configuration and status report
Web browser GUI Embedded GUI management interface
Web browser GUI Embedded GUI management interface
Web browser GUI Embedded GUI management interface
Management AP PathGuard, RAIDGuard Central, Windows MPIO, Windows VDS 1.1
Event Notification Built-in buzzer, e-mail, SNMP
Environment
Humidity 20% to 80% non-condensing
Operating Temp 5 °C to 40 °C
Non-Operating Temp -25 °C to 60 °C
Safety Regulatory UL, CUL, CB
EMC Standard FCC, CE, C-Tick, BSMI
Dimension & Weight
Physical Dimensions 485(W) x 565(D) x 132(H) mm
Physical Weight 24 Kgs (without drives)
Packed Dimensions 610(W) x 790(D) x 430(H) mm
Packed Weight 33 Kgs (without drives)
* Specifications and product offerings may vary without notice.

Key Features

Snapshot

The snapshot is done at the array and block level by leveraging the computing power of the RAID system, it is host-independent, and application-independent. It may cause less performance impact comparing to host-based snapshot software solutions. User is also allowed to restore data by using snapshot restore function. As a data image can be roller back to a snapshot immediately, user may resume applications without waiting.
Innovative New Array Stucture

The system features a new innovative array structure that hierarchically organizes storage objects. With this structure, physical drives are combined into Disk Groups (DG). Disk Groups are subdivided into Logical Disks (LD) where arrays are created. Lastly, Logical Disk can be combined or stripped together to form Volumes. Either volumes or LD can be pointed to a LUN which are then presented to the host computer.
Online Expansion and Defragmentation of Disk Groups

New physical disks can be added by expansion of a Disk Group (DG) while the unit remains online. During the process of expanding Disk Groups, defragmentation can be selected to move unused capacity to the ending LBA of a Disk Group. Defragmentation can also be selected at anytime there is unused storage space residing between Logical Disks.
Online Expansion and Shrinking of Logical Disks

Logical Disk (LD) Online Expansion can increase the capacity of an online LUN, instead of having to create a separate partition for unused capacity or capacity gained from Disk Group Expansion; now your storage can dynamically grow as your demands grow. In the event of overestimating requirements for Logical Disk capacity, shrinking can be used reduce the allocated storage of a Logical Disk.
JBOD Expansion

This newly added feature provides users the option to attach a JBOD unit to expand the capacity of their Arena storage solution. By allowing the SS-8801E/R to control the RAID-less JBOD units help reduce the total cost of ownership.
Array Recovery Utility

The system now provides an Array Recovery Utility (ARU) that can aid a user in the event of multiple drive failures corrupting the RAID array of a Logical Disk and/or volumes. The ARU enables users to recover lost disk members of a Disk Group, and will automatically recover Logical Disks and Volumes.
Global/local spare disks

With the new storage structure, local and global spares can be configured. Local spares will belong to specific Disk Groups and will only replace faulty drives in a specific Disk Group. Meanwhile, Global Spares will replace faulty disk in any available Disk Group.
Regenerate Parity

A simplified feature of Disk Scrubbing (DS), Regenerate Parity will regenerate the parity of a Logical Disk(s) in a Disk Group without a parity check.
Dual Flash Rom

Dual Flash ROM per controller gives higher RAID system availability and reliability during firmware upgrading or in the event of a single ROM failure.
Web-base GUI

Embedded CGI-based GUI (graphic user interface) management interface can be accessed through a web browser. The GUI allows users to easily setup RAID arrays, LUN mapping, etc. and also provides remote monitoring of drive health, fan, and power supplies.
Raid 6

RAID 6 improves over the industry standard RAID 5 by adding another parity disk which gives greater reliability and data protection.
Disk Self Test

Before the release of this function, users of RAID systems were forced to test suspected bad hard drives in a host computer individually using a drive manufacturer’s utility. This function tests the health of hard drives with them installed in the RAID unit. DST performs write tests, servo analysis, and read scan tests; the test results are then displayed on the LCD and hyper terminal output. This can aid the user in deciding whether or not to replace a suspected failing hard drive. We highly recommend running this test before initializing a RAID set to ensure a healthy RAID solution.
Disk Scrubbing

With today’s RAID subsystems being capable of storing multiple terabytes, it is becoming increasingly difficult to manage and maintain that large amount of data. To aid a user in maintaining their data’s health, Arena has released their newest firmware function Disk Scrubbing. The data and/or parity stored on hard drives can sometimes become corrupted; this data can also reside in areas that are not accessed for long periods of time. DS will use idle time to test the disks, and if a sector is found to be corrupted, the data will be regenerated from other RAID member disks and will be written to an uncorrupted sector. The purpose of DS is to prevent the possibility of having multiple corrupted sectors in a single stripe, which is one of the main causes of data loss.
Disk Clone

Hard drives are the most likely component to fail in a RAID array, and almost impossible to predict when the failure will occur. When a failure does occur the RAID unit will have to regenerate data from the non-failed hard drives to rebuild a new drive, and the RAID array will be in degraded mode. Having a unit in degraded mode is a very cautious time because if a second hard drive was to fail the RAID is destroyed and data is lost. This is where Disk Cloning can aide a user. With the help of the hard drives built in S.M.A.R.T. function, DC can determine when to begin cloning a bad drive to a hot spare. Upon completion of cloning, the new cloned disk can take the position of the failing disk or can stand-by until the original disk fails, then take the failed disks position. Disk cloning is to prevent a rebuild from ever occurring and having the unit in degraded mode.
Support greater than 2TB Lun

Two firmware options are available to surpass the 2 terabyte limitation; 16byte CDB and variable sector size. With either of these functions enabled, users are able to create slices and map LUNs greater than 2TB to their respective host channels. See support documentation for compatibility or contact technical support for more information.
Background Initialization

Initialization occurs during creation of a RAID array by zeroing out / formatting drives. By default the initialization process occurs with the unit offline, and inaccessible. With background initialization, the RAID array can be accessed during the initialization process so that the unit can be setup without having to wait several hours to complete initialization.
BBM

An optional BBM can be included in the RAID system to ensure data integrity in the event of a power outage. The BBM, or battery backup module, will provide power to the on-board cache of the RAID controller in the event of a power outage. This will allow any data that is still stored on the cache to be saved until power is restored. Once power is restored, the RAID controller will flush the cache to drives.

Downloads

User Manual: Hardware
SA-6651S Datasheet

GUI Preview

The Graphic User Interface, or GUI, is a RAID subsystem management tool which is operated using a web browser. It enables users to quickly and easily setup and configure the array, monitor status and performance, and enable event notification via SNMP and SMTP. The new GUI has many new functions and features that can greatly enhance your experience with Arena MaxTronics RAID products.
RAID Management

  • View health of hard drives
  • Setup Disk Groups, Logical Disks, and Volumes
  • Provision Storage
  • Maintenance

  • Online expansion of Disk Groups, and Logical Disks
  • Clone Hard drives
  • Run Disk Scrubbing, and Disk Self Test
  • Regenerate Parity of RAID arrays
  • Perform Array Roaming or Recovery
  • Tasks can be scheduled for a later time
  • Event Management

  • View event log in real time.
  • Configure SNMP, or SMTP event notification
  • Setup UPS monitoring and control
  • System Management

  • Restore settings to Factory Default
  • Save and Restore configurations to file, or member diskss
  • Setup Network connection, time, and security settings
  • View System Information
  • Update Firmware
  • Performance Management

  • View performance for individual hard disks, cache, luns, and storage ports
  • Spare Parts

    Photo Part No. Part Name Qty
    49-_06651-5002-001 Controller Module, for SA-6651S 1 set
    46-82410-5020-102 Fibre-to-SATA II Controller Board, for 3U 16Bay 1 piece
    46-08990-5000-120 LCD Button Board 1 piece
    46-58039-5000-210 IO Board 1 piece
    46-50034-5700-200 Back Plane, for 3U16bay SAS series 1 piece
    51-30000-5023 Power Supply, 460W 1 piece
    42-01620-5013 HDD Tray 1 piece
    42-00720-5001 Fan Set, for 2U series 1 set
    51-60000-5001 Rail 1 piece
    42-00000-5022 Extender 1 piece
    42-36000-5004 Key, 2pcs 1 set
    43-00003-5080 Power Cable-US, L=180cm 1 piece
    43-00003-5090 Power Cable-EU, L=180cm 1 piece
    43-00003-5100 Power Cable-AUS, L=180cm 1 piece
    43-00003-5110 Power Cable-PSE, L=180cm 1 piece
    43-00003-5120 Power Cable-UK, L=180cm 1 piece
    42-24632-5001 Screw Pack #M5, 2pcs 1 pack
    42-24645-5001 Screw Pack #M6, 2pcs 1 pack
    42-24045-5001 Screw Pack #10-32, 2pcs 1 pack
    43-00001-5001 RS232 Cable, L=180cm 1 piece
    49-00003-5016-001 BBM Module, 3U16bay/2U12bay 1 piece