Arena-MaxTronic SA-4540S is featuring twelve SATA II disk interface, dual Ultra 320 SCSI host channels, and an upgraded CPU result in an increased speed in data operation rate. In a compact 2U 12 bays chassis, featuring hot-swappable power supplies and fans. The RAID controller, fans, and power supplies are modularized allowing for easy removal from the rear of the unit.

Also featuring a web-based GUI that allows for remote configuration and monitoring through a web browser. The scalable, high performance and highly reliable features make it the ideal choice for DAS.

* Specifications are subject to change by Arena without notice

Overview

Idea Application

- Enterprise Storage
- Disk to Disk Backup
- Security and Surveillance
- Regulation Compliance Storage
- Disaster Recovery Storage

Specification

Hardware
Controller Single
Controller CPU Intel IOP331
Cache Memory 512 - 2048 MB DDR 333 SDRAM (PC2700 184-pin)
Battery Backup Module Optional
Host Interface Ultra 320 SCSI
Data Transfer Rate Up to 320MBps
Host Channels No. 2
Disk Interface SATA II (3Gbps)
Number of Disk Channels 12
Hot Swap Disk Tray 3.5" hot-swappable tray
Expansion SCSI Daisy Chain
External Connector Type VHDCI
Hot Swap Fan 2 x Turbo Fan
Hot Swap Power supplies 350W x 2 Redundant
AC Input Voltage 100 to 240V (+/- 10%), 47 to 63 Hz
RAID Functions
RAID Levels JBOD, 0, 1, 3, 5, 6, 10, 30, 50, TP, NRAID
RAID Features - Global Hotspare
- Multiple Host ID
- Multiple RAID Arrays and Multiple Slices
- Background Initialization
Advanced Data Reliability Assurance SMARTCor. Functions (DST, DS, DC)
Front Panel LCD and Buttons Easy access for configuration and status report
RS-232 Terminal User frirndly interface for configuration and status report
Web Browser GUI Embedded GUI management interface
Event Notification Built-in buzzer, e-mail
Environment
Humidity 20% to 80% non-condensing
Operating Temp 5 °C to 40 °C
Non-Operating Temp -25 °C to 60 °C
Safety Regulatory UL, CUL, CB
EMC Standard FCC, CE, C-Tick, BSMII
Dimension & Weight
Physical Dimensions 485(W) x 565(D) x 88(H) mm
Physical Weight 19 Kgs (without drives)
Packed Dimensions 610(W) x 790(D) x 430(H) mm
Packed Weight 28 Kgs (without drives)
* Specifications and product offerings may vary without notice.

Key Features

Dual Flash Rom

Dual Flash ROM per controller gives higher RAID system availability and reliability during firmware upgrading or in the event of a single ROM failure.
Web-Based GUI

Embedded web based GUI (graphic user interface) management interface can be accessed through a web browser. The GUI is java-based, and can configure arrays, slice sizes, lun mapping, etc. and also allows remote monitoring of drive health, fan, and power supplies.


Raid 6

RAID 6 improves over the industry standard RAID 5 by adding another parity disk which gives greater reliability and data protection.
Raid TP

The innovative RAID TP improves reliability even further than RAID 6 by creating an additional parity disk, for a total of three parity disks. RAID TP surpasses the reliability of RAID 5 and RAID 6 and can allow up to three disk failure while still maintaining access to data.
Disk Self Test(DST)

Before the release of this function, users of RAID systems were forced to test suspected bad hard drives in a host computer individually using a drive manufacturer’s utility. This function tests the health of hard drives with them installed in the RAID unit. DST performs write tests, servo analysis, and read scan tests; the test results are then displayed on the LCD and hyper terminal output. This can aid the user in deciding whether or not to replace a suspected failing hard drive. We highly recommend running this test before initializing a RAID set to ensure a healthy RAID solution.
Disks Scrubbing

With today’s RAID subsystems being capable of storing multiple terabytes, it is becoming increasingly difficult to manage and maintain that large amount of data. To aid a user in maintaining their data's health, Arena-MaxTronic has released their newest firmware function Disk Scrubbing. The data and/or parity stored on hard drives can sometimes become corrupted; this data can also reside in areas that are not accessed for long periods of time. DS will use idle time to test the disks, and if a sector is found to be corrupted, the data will be regenerated from other RAID member disks and will be written to an uncorrupted sector. The purpose of DS is to prevent the possibility of having multiple corrupted sectors in a single stripe, which is one of the main causes of data loss.
Disk Clone(DC)

With today’s RAID subsystems being capable of storing multiple terabytes, it is becoming increasingly difficult to manage and maintain that large amount of data. To aid a user in maintaining their data's health, Arena-MaxTronic has released their newest firmware function Disk Scrubbing. The data and/or parity stored on hard drives can sometimes become corrupted; this data can also reside in areas that are not accessed for long periods of time. DS will use idle time to test the disks, and if a sector is found to be corrupted, the data will be regenerated from other RAID member disks and will be written to an uncorrupted sector. The purpose of DS is to prevent the possibility of having multiple corrupted sectors in a single stripe, which is one of the main causes of data loss.
Support for greater than 2TB Lun

Two firmware options are available to surpass the 2 terabyte limitation; 16byte CDB and variable sector size. With either of these functions enabled, users are able to create slices and map LUNs greater than 2TB to their respective host channels. See support documentation for compatibility or contact technical support for more information.
Background Initialization

Initialization occurs during creation of a RAID array by zeroing out / formatting drives. By default the initialization process occurs with the unit offline, and inaccessible. With background initialization, the RAID array can be accessed during the initialization process so that the unit can be setup without having to wait several hours to complete initialization.
BBM

An optional BBM can be included in the RAID system to ensure data integrity in the event of a power outage. The BBM, or battery backup unit, will provide power to the on-board cache of the RAID controller in the event of a power outage. This will allow any data that is still stored on the cache to be saved until power is restored. Once power is restored, the RAID controller will flush the cache to drives.

Downloads

User Manual: Hardware
SA-4540S Datasheet

GUI Preview

The JanusRAID Graphic User Interface, or GUI, is a java-based RAID subsystem management tool which is operated using a web browser. It enables users to quickly and easily setup and configure the array, monitor status, and enable event notification via SNMP and SMTP. The GUI has many new functions and features that can greatly enhance your experience with Arena Maxtronic products.
Array Setup
  • Quickly create RAID arrays
  • Setup slices, and map LUNs
Array Utilities
  • Online Expand a RAID array
  • Modify RAID array settings, or delete an array
  • Setup and execute Disk Self Test, Disk Scrubbing, or Disk Clone
System Paramaters
  • Enable / Disable controller and disk cache
  • Setup Time, Network and Terminal settings
  • Change Administrator password
  • Configure SNMP and SMTP event notification
System Functions
  • Update Firmware
  • Reboot or prepare shutdown sequence

Spare Parts

Photo Part No. Part Name Qty
49-04540-5000-001 Controller Module, for SA-4540S 1 piece
46-89312-5510-200 Controller Board, for SA-xx40S 1 piece
46-00300-5001 Back Plane, for SA-4540S 1 piece
46-89230-5000-120 LCD Button Board 1 piece
51-30000-5004 Power Supply, 350W 1 piece
46-58039-5000-200 I/O Board 1 piece
42-01620-5013 HDD Tray 1 piece
42-00720-5001 Fan Set, for 3U Series 1 piece
51-60000-5001 Rail 1 piece
42-00000-5022 Extender 1 piece
42-36000-5004 Key, 2 pcs 1 pack
43-00003-5080 Power Cable-US, L=180cm 1 piece
43-00003-5090 Power Cable-EU, L=180cm 1 piece
43-00003-5100 Power Cable-AUS, L=180cm 1 piece
43-00003-5110 Power Cable-PSE, L=180cm 1 piece
43-00003-5120 Power Cable-UK, L=180cm 1 piece
43-00001-5001 RS232 Cable, L=180cm 1 piece
43-00320-5010 SCSI Cable, HPD-VHDCI (plastic), L=100cm 1 piece
43-00320-5020 SCSI Cable, VHDCI-VHDCI (plastic), L=100cm 1 piece
43-00001-5002 SCSI Cable, HPD-VHDCI, L=100cm
42-00001-5003 SCSI Cable, VHDCI-VHDCI, L=100cm
51-50000-5003 Terminator, LVD/SE VHDCI 1 piece
42-24632-5001 Screw #6/325mm, 30pcs 1 pack
42-24545-5001 Screw #M5, 2pcs 1 pack
42-24645-5001 Screw #M6, 2pcs 1 pack
42-24045-5001 Screw, #10/32, 2pcs 1 pack
49-00003-5016-001 BBM 1 piece